








🔌 Power your projects with confidence and style!
This 50-foot, 3/4-inch diameter liquid-tight conduit kit features durable 3 mm thick virgin PVC construction that resists corrosion and harsh chemicals. Designed for demanding environments, it includes 5 angle and 6 straight fittings for easy, flexible installation around curves and tight spaces. Perfect for routing power, control, and communication cables in industrial, outdoor, and residential applications.








| ASIN | B0B7QGKRFQ |
| Batteries Required? | No |
| Batteries included? | No |
| Brand | Wocloer |
| Colour | Gray |
| Customer Reviews | 4.4 4.4 out of 5 stars (74) |
| Date First Available | 29 Sept. 2022 |
| Guaranteed software updates until | unknown |
| Item Weight | 4.68 kg |
| Item model number | 1/2 |
| Manufacturer | Wocloer |
| Material | Polyvinyl Chloride (PVC) |
| Product Dimensions | 10 x 10 x 0.1 cm; 4.68 kg |
C**T
Just like advertised
J**N
Used this on my DIY 10.32kW solar array install. I used this in different sections for my installation. I eventually switched over to 1" diameter to ease my installation after changes. No concerns!
M**S
I purchased the WOCLOER Liquid-Tight Conduit for a simple project to run “Ubiquiti Unifi OS1 Simplex LC UPC Fiber Patch Cable” from my server room to my detached garage. The conduit was used for a 25-foot run under pavers and a garden area. My wife and I dug down 24 inches and placed the conduit in the trench. We also ran Gray Non-metallic Schedule 40 PVC Rigid conduit for an updated electric connection to the garage. Both conduit runs had three 90-degree bends and one 45. The pull string we needed for the cables installed in the rigid conduit without issue. We used the method of attaching a small plastic bag to the end of a string with a shop vac on the other end pulling the string through the pipe. The string FLEW through the rigid conduit in less than two seconds! The pull string method didn’t work at all with the flexible conduit. I applied copious amounts of Cable Pulling Lubricant to the tiny plastic bag. Fifteen minutes in… Nothing. I attached an air compressor to the end and after a few minutes struggle the string was FINALLY blown to the other end. With a Fiber Cable Pulling Eye firmly attached to the cable, I nervously started to pull the cable through the 25-foot length of WOCLOER Liquid-Tight Conduit. Installation of the cable in the conduit was impossible. The cable seemed to grip the inside of the tube and no amount of pulling lube helped free it from the sides of the conduit. Unfortunately, 10 minutes of pulling damaged the fiber cable beyond repair. We REPLACED the flexible conduit with Schedule 40 PVC Rigid conduit. The pull string flew through the conduit with the shop vac and the NEWLY purchased Fiber cable installed in less than thirty seconds. In an effort to not waste what I purchased, I tried to use a small STRAIGHT six-foot run of flexible conduit to connect a switch box inside my garage to another run and encountered the SAME issues I had earlier. I can’t recommend this kit at all.
N**V
I have bought 2 packages of this item. Works GREAT. Has a lot of fittings for your needs.
R**.
Pretty tough stuff worked great for me Thanks!
Trustpilot
1 month ago
1 week ago